Chiller installation manual






















liquid chillers installation, operation, maintenance supersedes: nm () form nm () issue date: february 6, hfca ld - tons - kw 2 compressor 50 and 60 hz model yvaa style a air-cooled screw liquid chillers with variable speed drive frame sizes - Title: YORK Model YT Style H Millennium Centrifugal Chiller Installation Instructions (Form N1) Keywords: York Centrifugal Liquid Chillers, CodePak, Millennium, thru tons, R R Styles F G, YDTL/LTL , , , used with YTG1G1E1 thru YTL6M6F2, YTA1A1B1 thru YTL6X6F2 and YTA1A1B1 thru YTL3X3E2 YDTJ-CB YTJ-CB . This operation manual concerns packaged air-cooled water chillers of the Daikin EWAD-MBYNN series. These units are provided for outdoor installation and used for cooling applications. The EWAD units can be combined with Daikin fan coil units or air handling units for air conditioning purposes. They can also be used for supplying water for.


Installation General This manual is intended to inform contractors, building owners, and engineers of the installation, commissioning, operation, and maintenance requirements for the PowerPax‐Smardt air cooled centrifugal chiller range. It is. MRI Chiller Installation Guidelines *These Items are the responsibility of the installing contractor to complete prior to the startup of the MRI Chiller.* **Please refer to DTS chiller manual for further info. Contact DTS at ‐‐ for questions or concerns with these items**. Shown below is a full list of our product Submittals, Installation Operation Manual's Please click on any link below to view a file (PDF). MACHE Air-Cooled Chiller.


ProcessFluid: Fill chiller and pipes with glycol mixture – Please refer to document MED‐WI‐ for further instruction. Glycol can be purchased from DTS, or sourced by the group installing the chiller. DTS recommends a 50% mix of inhibited propylene glycol to water. Installation contractor must provide distilled or DI water to mix with glycol (if not using pre‐mixed glycol). 45‐65+ gallons will be needed. TAP WATER IS NOT APPROVED TO MIX WITH GLYCOL. This manual contains the information needed to install and configure the Intelligent Equipment solution on MicroTech® II Water Cooled Chiller model WMC (Magnitude®); MicroTech III Air Cooled Chiller models: AGZ-D, AGZ-E, AWV, and AMZ (Pathfinder® and Trailblazer ®); Packaged Rooftop models: DPS (Rebel®) and MPS (Maverick® II), and Outdoor Air. chiller (see the certified drawings). Due to NEC (National Electric Code, U.S.A.) regulations, a minimum clearance of 4 ft ( mm) must be maintained on the side of the chiller that has an electrical box. Chiller fan discharge must be at least as high as adjacent solid walls. Installation in pits is not recom-mended. For 30RAP units, see Fig. 3.

0コメント

  • 1000 / 1000