Gas meter manual






















GX Operator’s Manual WARNING Read and understand this instruction manual before operating instrument. Improper use of the gas monitor could result in bodily harm or death. Periodic calibration and maintenance of the gas monitor is essential for proper operation and correct readings. Please calibrate and maintain this instrument regularly! this manual, contact your Company representative or call For additional copies of the Gas Service Manual, contact your Company representative or call Additional information on MidAmerican Energy’s rates and tariffs, and a current list of the communities served, can be found on our website:www.doorway.ru 7. recording monitor readings. This allows time for the gas to reach the instrument and for the sensors to react to any gases present. For example, 10 feet ( Meters) of tubing requires 2 minutes and 20 seconds of time to achieve accurate readings. CAUTION: Industrial Scientific recommends Teflon lined tubing, part number , be used.


GAS SERVICE MANUAL LIST OF FIGURES FIGURE 1 Preferred Location of Gas Meter Set 25 FIGURE 2 Clearance Zone Requirements from Vents and Air Intakes 26 REQUIREMENTS FOR GAS METER SETS 18 MANUFACTURED HOMES 20 MODIFICATION OF COMPANY GAS FACILITIES 22 DIVERSION OF SERVICE OR TAMPERING 23 FIGURES ALTAIR 4 - Operating Manual 7 • The minimum concentration of a combustible gas in air that can ignite is defined as the Lower Explosive Limit (LEL). A combustible gas reading of "XXX" indicates the atmosphere is above % LEL or % vol CH 4, and an explosion hazard exists. Move away from hazardous area immediately. SAGE THERMAL GAS MASS FLOW METER P R I M E USER MANUAL FOR PRIME FLOW METER MODEL SIP/SRP DOCUMENT NUMBER REVISION 30 05/03/ (SAGE PRIME™) SAGE METERING, INC. 8 Harris Court, Bldg. D Monterey, CA SAGE () Tel Fax www.doorway.ru


this manual, contact your Company representative or call For additional copies of the Gas Service Manual, contact your Company representative or call Additional information on MidAmerican Energy’s rates and tariffs, and a current list of the communities served, can be found on our website:www. If monitoring a different combustible gas in the % LEL range, calibrate the sensor using the appropriate gas. • Warning: High off-scale LEL readings may indicate an explosive concentration. • Only the combustible gas detection portion of this instrument has been assessed for performance by CSA International. Gas meter clearance piping distances gas meter dimensions: This article provides a detailed table of example clearance distance specifications for natural gas meter installation s, giving the distances to various building features such as windows, doors, electrical components, vents, air conditioners, and outside hose bibs. ##*“Go ahead.

0コメント

  • 1000 / 1000